THE COMMUNITY PORCH


ROLE | MODULAR CONSTRUCTION UNITS & PROGRAM LAYOUTS, RAINWATER HARVESTING SYSTEM, PLUMBING INTEGRATION SYSTEMS, LIGHTWELL INTEGRATION, 3D PRINTED MODEL & CALIBRATION

TEAM | MADILYN LAMBERT & ELIJAH HESS

The Community Porch is a modular, climate-responsive development in Knoxville designed at the intersection of civic gathering and passive environmental performance. Conceived as both a neighborhood threshold and an ecological engine, the architecture uses sculpted roof geometries calibrated for stormwater harvesting, prevailing-wind ventilation, and optimized daylighting. Illuminated translucent storefronts activate the street level, while deep internal lightwells draw natural light inward, creating an adaptable, multi-material framework dedicated to community connection and environmental resilience.

MODULAR ZONING & ROOF FORMATION


LOCATION | HOMBERG DRIVE, KNOXVILLE, TN

The second floor of the residential units features a layout built on a standardized modular framework. Prefabricated living and utility modules are stacked above an open-span commercial foundation that is constructed on-site. This design creates a clear spatial boundary between private living spaces and public areas.

MODULAR FABRICATION | PREFABRICATED ASSEMBLY, PLACEMENT, & PUBLIC-PRIVATE UNIT ZONING

1

2

Private Space

3

6

7

8

4

9

10

Modular Unit Apartment Suites

Ground Floor Commercial Space (Not Modular Construction)

Alignment

Contrast

Public Space

4’

8’

Modular Units Broken into Bedroom and Living Space Modules

6’

5

ROOF FORMS | ROOF PROFILE DISTRIBUTION

41 % offset of 14,400 gallons/week average

RAINWATER HARVESTING & PLUMBING INTEGRATION


1

2

Planter Box

  • 0.98” per sq/ft greenspace is needed per/week, which = 0.623 gallons/sq/ft per week of water

  • Special Case: Planters need roughly 1.5 gallons of water per week

  • Total Planter sq/ft: 367 sq/ft for 6 planters

  • Total Other Greenspace = 7,393 sq/ft

  • 1 Lightwell = 61.3 sq/ft : 4 Lightwells = 245.27 sq/ft

  • Roof Water Collection = 10,549.26 sq/ft

RAINWATER COLLECTION & IRRIGATION

  • Total water collection from roofs + lightwells = 10,550 + 245 = 10,795 sq/ft

  • Total Greenspace + Planter sq/ft = 7,760 sq/ft

IRRIGATION GREENSPACE & PLANTERS CALCULATION

  • Amount of water needed to irrigate each week:

    • Planters: 337 sq/ft x 1.5 gallons/week = 550.5 gallons/week

    • Other Greenspace: 7,393 sq/ft x 0.623 gallons/week = 4,605.8 gallons/week

    • Total gallons/week of water needed: 550.5 + 4,605.8 = 5,153.3 gallons/week

  • Amount of Usable Water Capture from Roofs + Lightwells (assuming 90% is usable):

    • 10,795 sq/ft x 0.98” per/week x 0.623 gallons/week x 0.9 (usable water) = 5,935.5 gallons/week of water collected

  • Therefore, we can irrigate planters and greenspace every week with our rainwater irrigation system, and have 777.7 gallons/week extra.

3

4

5

Lightwell Drip Edge

Cistern

Rain Chain

Water Collection Drain

$1,898.19

PROJECTED ANNUAL UTILITY SAVINGS

WATER SAVINGS

  • Withoverhead spray sprinklers, the city would supply the 10,795 sq/ft of greenspace + planters with 14,400 gallons/week of water

    Offset Calculation:

    • 5,931 gallons/week / 14,400 gallons/week = 0.4119 = 41.2% water saved

    • Our greenspace + planters would use 58.8% of the 14,400 gallons supplied per week

MONETARY SAVINGS

  • For spaces using over 20,000 gallons of water per month, the city of Knoxville charges $6.15 per 1000 gallons of water

  • Monthly Savings:

    • (5,935.5 x $6.15) / 1,000 = $36.50 per/week of savings ($158.05 per/month)

  • Annual Savings:

    • $36.50 x 52 weeks = $1,898.19 per/year of savings

STORAGE

  • Underground Plastic Rainwater Tank

  • 1 Tank holds 1,200 gallons of water

  • Building needs 5 x 1,200 gallon Rainwater Holding Tanks

Lightwell

40 Gallon Hot Water Heater

41%

TOTAL MUNICIPAL WATER OFFSET

14,400

Gallons/Week

KNOXVILLE RAINWATER PER/YR = 50-51”

CALCULATED STORMWATER CAPACITY CAPTURE

6

7

RESIDENTIAL

REFLECTED CEILING PLANS


1

2

Mezzanine: 5’ 8”

3

Drop Ceiling: 4’ 6”

Drop Ceiling: 2’ 3”

COMMERCIAL

RESIDENTIAL UNIT TYPE A

  • Square Footage: 1,250 sq/ft

  • Number of Residential Units: 1 Unit

  • Public-to-Private Opening Dimension: 31’

  • Module Dimensions: 40’ x 12’ x 8’

UNIT LAYOUT INTEGRATION & SPATIAL SYSTEMS COORDINATION


1

2

Exhaust Vent

Lightwell

RESIDENTIAL UNIT TYPE B

  • Square Footage: 913 sq/ft

  • Number of Residential Units: 2 Units

  • Public-to-Private Opening Dimension: 7.5’

  • Module Dimensions: 12’ x 40’ x 8’

3

4

Hot Water Heater Above

Exhaust Vent above Ceiling

6

5

Cassette

Washer/Dryer in Mechanical Closet

7

Mezzanine

RESIDENTIAL UNIT TYPE C

  • Square Footage: 889 sq/ft

  • Number of Residential Units: 1 Unit

  • Public-to-Private Opening Dimension: 7’

  • Module Dimensions: 12’ x 40’ x 8’ and 12’ x 27’ x 8’

ENVELOPE TECTONICS & THERMAL BOUNDARIES


The perimeter enclosure is a high-performance assembly designed to reduce thermal bridging and support rain-collection pathways. To reduce conductive thermal short circuits and prevent interstitial wall condensation, a continuous exterior rigid insulation barrier encloses the structural framing assembly. The multi-layered exterior wall transitions from a Corten standing-seam roof (R-60.31) to a continuous terracotta rainscreen envelope (R-31.38), using integrated weather membranes and continuous air cavities to prevent moisture penetration. The central lightwell core features operable window tracks, creating a passive stack-ventilation system within the daylighting cavity. The system naturally transfers thermal loads from the lower commercial areas while directing roof runoff into subgrade site filtration cisterns via a drip-edge gutter system.

LIGHTWELL RAIN COLLECTION AT FOUNDATION

1

2

  • 1/4” Geotextile Fabric

  • Weather Membrane

  • Metal Slope to Drainage System

2” Irrigation Pipe to Cistern

3

4

Rain Collection Sloped Channel Drain

  • 1/4” Geotextile Fabric

  • Weather Membrane

  • 4” Concrete Retaining Wall

  • 2” Mineral Wool Rigid Insulation

  • Vapor Barrier

5

6

7

8

9

10

  • 12” Soil Layer

  • 1/4” Geotextile Fabric

  • 12” Gravel Layer

  • 1/4” Geotextile Fabric

  • Atlantis Flo Cell 0.79” (x3) - Neocell

Wood Blocking

Aluminum Sloped Parapet

Aluminum Mill

  • 3/4” Hardwood Floor

  • 3/4” Plywood

  • 4” Concrete Retaining Wall

  • Weather Membrane

  • 2” Mineral Wool Rigid Insulation

  • Vapor Barrier

  • Gravel

  • 1/4” Geotextile Fabric

2250 IG Curtain Wall System Type “B” Screw Spline Assembly 4-1/2” System (1” & 1/4” Infill)

LIGHTWELL SECTION

1

2

3

4

5

6

ROOF ASSEMBLY - TOTAL R: 60.31

  • Corten Standing Seam Panel

  • 2” Mineral Wool Rigid Insulation

  • Weather Membrane

  • 1/4” Densglass Sheathing

  • 12” Mineral Wool Batt Insulation

  • 5/8” Gypsum Board

Roof Drip Edge

TERRACOTTA WALL ASSEMBLY - Total R: 31.38

  • Terracotta Rain Screen

  • Air Gap

  • 1” Mineral Wool Rigid Insulation

  • Weather Membrane

  • 5/8“ Densglass Sheathing

  • 6” Mineral Wool Batt Insulation

  • 5/8” Gypsum Board

Wood Truss

WINDOW ASSEMBLY - Total R: 1.61

  • Double Pane Glass

Skylight Ventilation Window‍ ‍

LIGHTWELL WALL SECTION - 2B

PHYSICAL FABRICATION & SPATIAL PROTOTYPING


As a multi-material prototype, the physical 3D Model was created on an optimized Bambu Lab A1 Mini platform using calibrated parameters in Bambu Studio.

The structural components use a material pairing: dense PLA Matte outlines the opaque structural framing and perimeter envelope, while specialized Translucent PETG lets integrated internal lighting cavities diffuse light through the translucent commercial storefront and internal light wells.

FABRICATION METHODOLOGY & ADVANCED PRINT CALIBRATION

To troubleshoot warping, stringing, and overall model cleanliness, I tweaked advanced settings in Bambu Studio to finalize the 3D Model. During slicing, I adjusted retraction speed and distance, bed temperature calibration, seam position, infill and density, layer speeds, outer and inner wall speeds, and auxiliary cooling fan settings, along with other micro-performance tweaks. To ensure the final print's readability, we continuously tweaked advanced print settings and printed and analyzed several part iterations. The final assembly incorporates a custom-spliced LED wire harness embedded in the print, anchored by a series of flush-fit magnets that secure the residential upper floor while allowing seamless, non-destructive removal for section-cut evaluation.